Actively exploited vulnerability / CVE-2026-83548
SonicWall SMA1000: attackers on the internet can reach sensitive functions without a login
A flaw in the Work Place portal of SonicWall SMA1000 appliances lets an attacker on the internet, with no account or password, reach sensitive functions of the device and carry out unauthorized operations. Because this device controls remote access to the company network, a compromise can open the way to internal systems and data. The vulnerability is on the lists of vulnerabilities used in real attacks kept by CISA, the US cybersecurity agency, and by ENISA, the EU cybersecurity agency.
- Identifier
- CVE-2026-83548 · EUVD-2026-69704
- Severity
- Critical (10/10)
- On the CISA list (US)
- yes, since 2 September 2026
- Deadline given to US federal agencies
- 5 September 2026
- On the ENISA list (EU)
- yes
- Probability of exploitation (EPSS)
- 8.0% (FIRST's estimate for the next 30 days)
Does it concern you?
SonicWall SMA1000 is a secure remote access appliance that employees use to connect to the company network from outside the office. It is typically found in companies that support remote work, managed by an IT provider or an in-house team.
The version is shown in the appliance's administration interface under system information, or you can ask whoever manages your network. Affected are versions older than 12.4.3-03526, and 12.5.0 series versions older than 12.5.0-02952.
Affected products and versions
- SonicWall SMA1000 Appliances
- sma8200v: before 12.4.3-03526; from 12.5.0 before 12.5.0-02952
- sma6210 firmware: before 12.4.3-03526; from 12.5.0 before 12.5.0-02952
- sma7210 firmware: before 12.4.3-03526; from 12.5.0 before 12.5.0-02952
What to do
Update the appliance to version 12.4.3-03526 or 12.5.0-02952, or later, following SonicWall's instructions. Then ask your administrator to check whether the device has already been accessed without authorization.
Versions that contain the fix: 12.4.3-03526, 12.5.0-02952.
The official description
The text below is the description from the public database.
A Pre-authentication SSRF vulnerability exists in the SMA1000 Appliance Work Place interface due to an unintended alternate access path. A remote unauthenticated attacker could potentially exploit this vulnerability to gain unauthorized access to sensitive functionality and perform unauthorized operations.
Sources
- CVE Program
- Vendor advisory: psirt.global.sonicwall.com
- Vendor advisory: cisa.gov
- Vendor advisory: nvd.nist.gov
- GitHub Advisory Database
- NVD
- ENISA EUVD
Data from the public CVE and NVD databases, the CISA KEV and ENISA EU KEV lists and FIRST's EPSS score. The explanations are ours, written from that data. Last updated: 29 November 2026.