cybersecurity Request an audit

Actively exploited vulnerability / CVE-2025-23006

SonicWall SMA1000: an attacker can take control of the remote access appliance

This flaw in the management consoles of SonicWall SMA1000 appliances can let an attacker on the internet, with no account or password, run commands on the device. Because this appliance controls how staff reach the company network, whoever takes it over may move on to internal data and systems. It is on the lists of vulnerabilities used in real attacks kept by CISA (the US cybersecurity agency) and by ENISA (the EU cybersecurity agency).

Identifier
CVE-2025-23006 · EUVD-2025-3070
Severity
Critical (9.8/10)
On the CISA list (US)
yes, since 24 January 2025
Deadline given to US federal agencies
14 February 2025
On the ENISA list (EU)
yes
Probability of exploitation (EPSS)
2.4% (FIRST's estimate for the next 30 days)

Does it concern you?

SonicWall SMA1000 is a secure remote access appliance that lets employees connect to the company network from outside the office. It is typically found in companies that use SonicWall equipment and allow remote or field work.

The firmware version is shown in the appliance's management console; if you are unsure where to look, ask whoever manages your network. Affected are the SMA 6200, 6210, 7200, 7210 and 8200v models on versions older than 12.4.3-02854, and the older SRA EX6000, EX7000 and EX9000 models on versions up to and including 12.4.3-02804.

Affected products and versions

  • SonicWall SMA1000 Appliances
  • sma8200v: before 12.4.3-02854
  • sma6200 firmware: before 12.4.3-02854
  • sma6210 firmware: before 12.4.3-02854
  • sma7200 firmware: before 12.4.3-02854
  • sma7210 firmware: before 12.4.3-02854
  • sra ex6000 firmware: up to and including 12.4.3-02804
  • sra ex7000 firmware: up to and including 12.4.3-02804
  • sra ex9000 firmware: up to and including 12.4.3-02804

What to do

Update to version 12.4.3-02854 or later and follow SonicWall's instructions. If the vendor offers no fix for your device, stop using it.

Versions that contain the fix: 12.4.3-02854.

The official description

The text below is the description from the public database.

Pre-authentication deserialization of untrusted data vulnerability has been identified in the SMA1000 Appliance Management Console (AMC) and Central Management Console (CMC), which in specific conditions could potentially enable a remote unauthenticated attacker to execute arbitrary OS commands.

Sources

Data from the public CVE and NVD databases, the CISA KEV and ENISA EU KEV lists and FIRST's EPSS score. The explanations are ours, written from that data. Last updated: 29 November 2026.

Other exploited vulnerabilities in SonicWall SMA1000 Appliances

All exploited vulnerabilities in SonicWall SMA1000 Appliances

What you can do next

Request an audit

Find out what you expose, before someone else does.

Tell us who you are, confirm by email, and we will call you. Nothing is checked until you agree.

  1. You confirm by email, then we call you within two working days to understand your company and what should be checked.
  2. You get a fixed quote and a permission form that says exactly what we may test, and when.
  3. We do the work in the window you chose, and keep you posted.
  4. You get the report and a walkthrough call, then one retest of its findings within 30 days.

Only systems you own or may have checked / written permission first

Request an audit

No passwords or access details here. We ask for what we need after you sign the permission form.

After you send this, we email you a link to confirm it. We contact you only after you confirm.