cybersecurity Request an audit

Actively exploited vulnerability / CVE-2026-111560

Barracuda appliances: an administrator account can take full control of the device

This vulnerability lets someone with administrator access to a Barracuda appliance run their own commands with the highest privileges on the device. In practice, anyone who gains or steals an administrator account can take complete control of the appliance that filters your email, web traffic or applications, and could read or change data or disrupt the service. It is on the lists of vulnerabilities used in real attacks kept by CISA (the US cybersecurity agency) and by ENISA (the EU cybersecurity agency).

Identifier
CVE-2026-111560 · EUVD-2026-115148
On the CISA list (US)
yes, since 10 November 2026
Deadline given to US federal agencies
13 November 2026
On the ENISA list (EU)
yes
Probability of exploitation (EPSS)
10.8% (FIRST's estimate for the next 30 days)

Does it concern you?

Several Barracuda appliances are affected: Email Security Gateway, Load Balancer, Application Delivery Controller, Message Archiver, WAF Control Center, Web Application Firewall and Web Security Gateway. They are typically used by companies that protect their email, websites or internet access with Barracuda products, often installed and managed by an IT provider.

Find out whether your company runs any of these Barracuda appliances; the version is usually shown in the administration interface, in the system information section. If you are unsure, ask whoever manages your network.

Affected products and versions

  • Barracuda Networks Multiple Products

What to do

Apply the mitigations and updates Barracuda recommends for your appliance, following the vendor's instructions. If no fix is available, consider stopping use of the product until one is, and review who has administrator access to it.

The official description

The text below is the description from the public database.

Improper neutralization of shell metacharacters in the timezone configuration field in certain Barracuda appliance products using common Barracuda code allows an authenticated administrator to inject OS commands that execute with root privileges when the crafted timezone value is subsequently processed.

Sources

Data from the public CVE and NVD databases, the CISA KEV and ENISA EU KEV lists and FIRST's EPSS score. The explanations are ours, written from that data. Last updated: 29 November 2026.

What you can do next

Request an audit

Find out what you expose, before someone else does.

Tell us who you are, confirm by email, and we will call you. Nothing is checked until you agree.

  1. You confirm by email, then we call you within two working days to understand your company and what should be checked.
  2. You get a fixed quote and a permission form that says exactly what we may test, and when.
  3. We do the work in the window you chose, and keep you posted.
  4. You get the report and a walkthrough call, then one retest of its findings within 30 days.

Only systems you own or may have checked / written permission first

Request an audit

No passwords or access details here. We ask for what we need after you sign the permission form.

After you send this, we email you a link to confirm it. We contact you only after you confirm.