cybersecurity Request an audit

Actively exploited vulnerability / CVE-2025-67038

Lantronix EDS5000: an attacker can take full control of the device

A flaw in the web interface of the Lantronix EDS5000 lets an attacker run their own commands on the device with full privileges, without needing a valid account. This means they can take over the device, read or alter the data passing through it, and use it as a foothold into the company network. It is on the lists of vulnerabilities used in real attacks kept by CISA (the US cybersecurity agency) and by ENISA (the EU cybersecurity agency).

Identifier
CVE-2025-67038 · EUVD-2025-208587
Severity
Critical (9.3/10)
On the CISA list (US)
yes, since 23 June 2026
Deadline given to US federal agencies
26 June 2026
On the ENISA list (EU)
yes
Probability of exploitation (EPSS)
2.6% (FIRST's estimate for the next 30 days)

Does it concern you?

The EDS5000 is a device server that connects equipment with serial ports, such as industrial, medical or lab machines and access control systems, to the network. It is typically found in factories, hospitals, warehouses and buildings with older technical equipment.

The firmware version is usually shown on the status page of the device's web interface; if you are unsure, ask your supplier or whoever manages the equipment. Version 2.1.0.0R3 is affected, and on certain related models versions earlier than 3.21.0.0R1 are affected.

Affected products and versions

  • Lantronix EDS5000
  • e213f102s firmware: before 3.21.0.0R1
  • e214f002s firmware: before 3.21.0.0R1
  • e214f00cs firmware: before 3.21.0.0R1
  • e214g000s firmware: before 3.21.0.0R1
  • e214g001s firmware: before 3.21.0.0R1
  • e218f004s firmware: before 3.21.0.0R1
  • e218g107s firmware: before 3.21.0.0R1
  • e228g002s firmware: before 3.21.0.0R1
  • e228g004s firmware: before 3.21.0.0R1
  • e228g00cb28 firmware: before 3.21.0.0R1
  • and 23 more products in the public analysis

What to do

Install a fixed firmware version: 2.2.0.0r1, 2.6.0.4R6 or 3.21.0.0R1 as applicable, following Lantronix's instructions. Until then, make sure the device's web interface cannot be reached from the internet.

Versions that contain the fix: 2.2.0.0r1, 2.6.0.4R6, 3.21.0.0R1.

The official description

The text below is the description from the public database.

An issue was discovered in Lantronix EDS5000 2.1.0.0R3. The HTTP RPC module executes a shell command to write logs when user's authentication fails. The username is directly concatenated with the command without any sanitization. This allow attackers to inject arbitrary OS commands into the username parameter. Injected commands are executed with root privileges.

Sources

Data from the public CVE and NVD databases, the CISA KEV and ENISA EU KEV lists and FIRST's EPSS score. The explanations are ours, written from that data. Last updated: 29 November 2026.

What you can do next

Request an audit

Find out what you expose, before someone else does.

Tell us who you are, confirm by email, and we will call you. Nothing is checked until you agree.

  1. You confirm by email, then we call you within two working days to understand your company and what should be checked.
  2. You get a fixed quote and a permission form that says exactly what we may test, and when.
  3. We do the work in the window you chose, and keep you posted.
  4. You get the report and a walkthrough call, then one retest of its findings within 30 days.