Actively exploited vulnerability / CVE-2023-4346

KNX building automation: attackers can lock devices so you cannot regain access

This vulnerability lets an attacker wipe KNX devices that lack additional security options and lock them with a password that cannot be reset without knowing the current one. You could lose control of lighting, heating, blinds or other building functions, and restoring the installation can take time and money. It is on the lists of vulnerabilities used in real attacks kept by CISA (the US cybersecurity agency) and by ENISA (the EU cybersecurity agency).

Identifier
CVE-2023-4346 · EUVD-2023-54211
Severity
High (7.5/10)
On the CISA list (US)
yes, since 15 July 2026
Deadline given to US federal agencies
29 July 2026
On the ENISA list (EU)
yes
Probability of exploitation (EPSS)
1.3% (FIRST's estimate for the next 30 days)

Does it concern you?

KNX is a standard for building automation such as lighting, climate control, blinds and access control. It is common in offices, hotels, commercial buildings and modern homes, especially where the installation can be controlled over a network.

Affected are KNX devices using Connection Authorization Option 1, depending on how the manufacturer implemented it. Ask the integrator or company that installed your KNX system whether your devices are affected and whether the installation is reachable from a network.

Affected products and versions

  • KNX Association KNX Protocol Connection Authorization Option 1

What to do

Apply the mitigations recommended by the manufacturer and KNX Association with your integrator's help, including enabling the additional security options. Restrict access to the KNX network and devices, and if no mitigations are available, consider replacing the affected equipment.

The official description

The text below is the description from the public database.

KNX devices that use KNX Connection Authorization and support Option 1 are, depending on the implementation, vulnerable to being locked and users being unable to reset them to gain access to the device. The BCU key feature on the devices can be used to create a password for the device, but this password can often not be reset without entering the current password. If the device is configured to interface with a network, an attacker with access to that network could interface with the KNX installation, purge all devices without additional security options enabled, and set a BCU key, locking the device. Even if a device is not connected to a network, an attacker with physical access to the device could also exploit this vulnerability in the same way.

Sources

Data from the public CVE and NVD databases, the CISA KEV and ENISA EU KEV lists and FIRST's EPSS score. The explanations are ours, written from that data. Last updated: 29 November 2026.

What you can do next

Request an audit

Find out what you expose, before someone else does.

Tell us who you are, confirm by email, and we will call you. Nothing is checked until you agree.

  1. You confirm by email, then we call you within two working days to understand your company and what should be checked.
  2. You get a fixed quote and a permission form that says exactly what we may test, and when.
  3. We do the work in the window you chose, and keep you posted.
  4. You get the report and a walkthrough call, then one retest of its findings within 30 days.

Only systems you own or may have checked / written permission first

Request an audit

No passwords or access details here. We ask for what we need after you sign the permission form.

After you send this, we email you a link to confirm it. We contact you only after you confirm.