Actively exploited vulnerability / CVE-2021-22681
Rockwell Logix: industrial controllers may accept connections from unauthorized apps
This flaw lets an attacker with network access bypass the check that Logix controllers use to recognize Rockwell's programming software, and connect to them without authorization. For a business with automated production, this means an outsider could end up communicating with the equipment that runs its lines and machines. It is on the lists of vulnerabilities used in real attacks kept by both CISA (the US cybersecurity agency) and ENISA (the EU cybersecurity agency).
- Identifier
- CVE-2021-22681 · EUVD-2021-9817
- Severity
- Critical (9.8/10)
- On the CISA list (US)
- yes, since 5 March 2026
- Deadline given to US federal agencies
- 26 March 2026
- On the ENISA list (EU)
- yes
- Probability of exploitation (EPSS)
- 63.6% (FIRST's estimate for the next 30 days)
Does it concern you?
This concerns Rockwell Automation industrial controllers (CompactLogix, ControlLogix, DriveLogix, GuardLogix, Compact GuardLogix, SoftLogix) and the Studio 5000 Logix Designer and RSLogix 5000 programming software. They are typically found in factories, production lines, pumping stations and other automated facilities.
Affected are RSLogix 5000 versions 16 through 20, Studio 5000 Logix Designer version 21 and later, and FactoryTalk Services Platform from version 2.10, together with the controllers listed above. Ask the integrator or automation engineer who looks after your installations which controller models and software versions you use.
Affected products and versions
- Rockwell Multiple Products
- factorytalk services platform: from 2.10
- rslogix 5000: from 16 up to and including 20
- studio 5000 logix designer: from 21.0
What to do
Apply the protective measures Rockwell Automation recommends for this issue, with help from your integrator. If those measures cannot be applied, the advice is to stop using the affected product.
The official description
The text below is the description from the public database.
Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.
Sources
- CVE Program
- GitHub Advisory Database
- Vendor advisory: support.rockwellautomation.com
- Vendor advisory: cisa.gov
- Vendor advisory: nvd.nist.gov
- NVD
- ENISA EUVD
Data from the public CVE and NVD databases, the CISA KEV and ENISA EU KEV lists and FIRST's EPSS score. The explanations are ours, written from that data. Last updated: 29 November 2026.