cybersecurity Request an audit

Actively exploited vulnerability / CVE-2020-3580

Cisco ASA and FTD: a booby-trapped link can expose data in a user's browser

This flaw lets a remote attacker without an account run code in the device's web interface if a user clicks a specially prepared link. The attacker could then obtain sensitive information from that user's browser, such as data used to access the company network. It is on the lists of vulnerabilities used in real attacks kept by CISA (the US cybersecurity agency) and ENISA (the EU cybersecurity agency).

Identifier
CVE-2020-3580 · EUVD-2020-24851
Severity
Medium (6.1/10)
On the CISA list (US)
yes, since 3 November 2021
Deadline given to US federal agencies
3 May 2022
On the ENISA list (EU)
yes
Probability of exploitation (EPSS)
85.6% (FIRST's estimate for the next 30 days)

Does it concern you?

Cisco ASA and Firepower Threat Defense are firewalls many companies use to protect their network and provide remote VPN access (AnyConnect or WebVPN). Only certain AnyConnect and WebVPN configurations are affected.

The software version is shown in the device's management interface; if you do not manage it yourself, ask your IT provider. Affected are ASA versions before 9.8.4.34, the 9.9 to 9.15 series before the fixed releases below, and FTD versions before 6.4.0.12, from 6.5.0 up to before 6.6.4, and from 6.7.0 up to before 6.7.0.2.

Affected products and versions

  • Cisco Adaptive Security Appliance (ASA) and Firepower Threat Defense (FTD)
  • secure firewall threat defense: before 6.4.0.12; from 6.5.0 before 6.6.4; from 6.7.0 before 6.7.0.2
  • adaptive security appliance software: before 9.8.4.34; from 9.9 before 9.9.2.85; from 9.10 before 9.12.4.13; from 9.13 before 9.13.1.21; from 9.14 before 9.14.2.8; from 9.15 before 9.15.1.15

What to do

Install the Cisco update for your release line: for ASA 9.8.4.34, 9.12.4.13, 9.13.1.21, 9.14.2.8 or 9.15.1.15 or later, and for FTD 6.4.0.12, 6.6.4 or 6.7.0.2 or later. For the 9.9 line, follow Cisco's update guidance.

Versions that contain the fix: 6.4.0.12, 6.6.4, 6.7.0.2, 9.12.4.13, 9.13.1.21, 9.14.2.8, 9.15.1.15, 9.8.4.34.

The official description

The text below is the description from the public database.

Multiple vulnerabilities in the web services interface of Cisco Adaptive Security Appliance (ASA) Software and Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to conduct cross-site scripting (XSS) attacks against a user of the web services interface of an affected device. The vulnerabilities are due to insufficient validation of user-supplied input by the web services interface of an affected device. An attacker could exploit these vulnerabilities by persuading a user of the interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface or allow the attacker to access sensitive, browser-based information. Note: These vulnerabilities affect only specific AnyConnect and WebVPN configurations. For more information, see the Vulnerable Products section.

Sources

Data from the public CVE and NVD databases, the CISA KEV and ENISA EU KEV lists and FIRST's EPSS score. The explanations are ours, written from that data. Last updated: 29 November 2026.

Other exploited vulnerabilities in Cisco Adaptive Security Appliance (ASA) and Firepower Threat Defense (FTD)

All exploited vulnerabilities in Cisco Adaptive Security Appliance (ASA) and Firepower Threat Defense (FTD)

What you can do next

Request an audit

Find out what you expose, before someone else does.

Tell us who you are, confirm by email, and we will call you. Nothing is checked until you agree.

  1. You confirm by email, then we call you within two working days to understand your company and what should be checked.
  2. You get a fixed quote and a permission form that says exactly what we may test, and when.
  3. We do the work in the window you chose, and keep you posted.
  4. You get the report and a walkthrough call, then one retest of its findings within 30 days.

Only systems you own or may have checked / written permission first

Request an audit

No passwords or access details here. We ask for what we need after you sign the permission form.

After you send this, we email you a link to confirm it. We contact you only after you confirm.