Actively exploited vulnerability / CVE-2017-3881
Cisco switches: an attacker can take full control of them or restart them
This flaw in Cisco IOS and IOS XE software lets an attacker, without a password and over the network, take full control of a switch or force it to restart. For a business this can mean an internal network outage, or an intruder able to see and redirect traffic between computers and servers. It is on the lists of vulnerabilities used in real attacks kept by CISA, the US cybersecurity agency, and by ENISA, the EU cybersecurity agency.
- Identifier
- CVE-2017-3881 · EUVD-2017-12998
- Severity
- Critical (9.8/10)
- On the CISA list (US)
- yes, since 25 March 2022
- Deadline given to US federal agencies
- 15 April 2022
- On the ENISA list (EU)
- yes
- Probability of exploitation (EPSS)
- 99.0% (FIRST's estimate for the next 30 days)
Does it concern you?
This concerns Cisco network equipment, especially Catalyst switches, IE Industrial Ethernet switches, EtherSwitch service modules and other models listed by Cisco. They are usually found in the server room or network cabinet of companies with a larger wired network.
Ask your IT provider or network administrator which IOS or IOS XE version your Cisco switches run and whether Telnet access is enabled. IOS versions from 12.2S up to and including 15.1(3)SVS and IOS XE versions from 3.2SG up to and including 3.9E are affected.
Affected products and versions
- Cisco IOS and IOS XE
- ios: from 12.2s up to and including 15.1\(3\)svs
- ios xe: from 3.2sg up to and including 3.9e
What to do
Install the update Cisco provides for your model, following the vendor's instructions. Until then, ask your administrator to turn off Telnet access if it is not needed, in line with Cisco's guidance.
The official description
The text below is the description from the public database.
A vulnerability in the Cisco Cluster Management Protocol (CMP) processing code in Cisco IOS and Cisco IOS XE Software could allow an unauthenticated, remote attacker to cause a reload of an affected device or remotely execute code with elevated privileges. The Cluster Management Protocol utilizes Telnet internally as a signaling and command protocol between cluster members. The vulnerability is due to the combination of two factors: (1) the failure to restrict the use of CMP-specific Telnet options only to internal, local communications between cluster members and instead accept and process such options over any Telnet connection to an affected device; and (2) the incorrect processing of malformed CMP-specific Telnet options. An attacker could exploit this vulnerability by sending malformed CMP-specific Telnet options while establishing a Telnet session with an affected Cisco device configured to accept Telnet connections. An exploit could allow an attacker to execute arbitrary code and obtain full control of the device or cause a reload of the affected device. This affects Catalyst switches, Embedded Service 2020 switches, Enhanced Layer 2 EtherSwitch Service Module, Enhanced Layer 2/3 EtherSwitch Service Module, Gigabit Ethernet Switch Module (CGESM) for HP, IE Industrial Ethernet switches, ME 4924-10GE switch, RF Gateway 10, and SM-X Layer 2/3 EtherSwitch Service Module. Cisco Bug IDs: CSCvd48893.
Sources
Data from the public CVE and NVD databases, the CISA KEV and ENISA EU KEV lists and FIRST's EPSS score. The explanations are ours, written from that data. Last updated: 29 November 2026.