cybersecurity Request an audit

Actively exploited vulnerability / CVE-2015-2291

Intel Ethernet diagnostics driver for Windows can let attackers crash or take over PCs

This flaw lets an attacker who already has access to a Windows computer crash it or possibly run code with the highest level of system privileges. That can turn limited access into full control of the machine, letting an attacker bypass protections and reach company data. It is on the lists of vulnerabilities used in real attacks kept by both CISA (the US cybersecurity agency) and ENISA (the EU cybersecurity agency).

Identifier
CVE-2015-2291 · EUVD-2015-2389
Severity
High (7.8/10)
On the CISA list (US)
yes, since 10 February 2023
Deadline given to US federal agencies
3 March 2023
On the ENISA list (EU)
yes
Probability of exploitation (EPSS)
15.7% (FIRST's estimate for the next 30 days)

Does it concern you?

This is an Intel driver used to diagnose Ethernet network cards on Windows computers and servers. It may be installed along with Intel network software, especially on systems with Intel network cards.

The affected files are IQVW32.sys and IQVW64.sys in versions earlier than 1.3.1.0; the version appears in the file's properties in the Windows drivers folder. If you are unsure where to look, ask whoever manages your IT.

Affected products and versions

  • Intel Ethernet Diagnostics Driver for Windows

What to do

Update the driver to version 1.3.1.0 or later, following Intel's instructions. If you do not use Intel's diagnostic tools, ask your IT contact about removing the driver.

The official description

The text below is the description from the public database.

(1) IQVW32.sys before 1.3.1.0 and (2) IQVW64.sys before 1.3.1.0 in the Intel Ethernet diagnostics driver for Windows allows local users to cause a denial of service or possibly execute arbitrary code with kernel privileges via a crafted (a) 0x80862013, (b) 0x8086200B, (c) 0x8086200F, or (d) 0x80862007 IOCTL call.

Sources

Data from the public CVE and NVD databases, the CISA KEV and ENISA EU KEV lists and FIRST's EPSS score. The explanations are ours, written from that data. Last updated: 29 November 2026.

What you can do next

Request an audit

Find out what you expose, before someone else does.

Tell us who you are, confirm by email, and we will call you. Nothing is checked until you agree.

  1. You confirm by email, then we call you within two working days to understand your company and what should be checked.
  2. You get a fixed quote and a permission form that says exactly what we may test, and when.
  3. We do the work in the window you chose, and keep you posted.
  4. You get the report and a walkthrough call, then one retest of its findings within 30 days.

Only systems you own or may have checked / written permission first

Request an audit

No passwords or access details here. We ask for what we need after you sign the permission form.

After you send this, we email you a link to confirm it. We contact you only after you confirm.